SMT Quality Control
Bonding
1. Nozzle Control
IPA is not so effective to clean up inner part of nozzle, acetone is more
recommendable (except clogging bond being untouched for certain hours.)
Ultrasonic Cleaning is also recommendable. After cleaning, every inner part of
nozzle must be inspected by
micro-scope by lighting-up the inside from bottom. Certainly, we also must check
nozzle lacking or transformation, which will cause unstable bonding as well as
lacking chip nozzle causes lower mounting rate. Better input firmly the original
nozzle shape and performance so as for easier judgment.
2. Bond Control
Keep it in refrigerator, vertically with nozzle-top down. When production is
stopped at the half-way, keep it together with nozzle in the refrigerator is
still yet to cause any problems. (However, if more than 24 hrs stoppage, nozzle
must be removed.)
Sometimes, we can see a problematic bonding, where the bond spreads wider than
the diameter of nozzle and higher than the height of nozzle.
|
(NG)
|
(Good)

(Expandable)
(Solid)
If the bonding is unstable, machine maintenance or calibration for more than 1
year must be carried out. Regardless of regular calibration, if still the
bonding is still unstable, wear & tear of nozzle or O-Ring must be checked.
Secondly, bond itself may be deteriorated. As there are many factors have to be
considered, field experiment and patience are strictly required.
:: Written by Rising Dragon, 29-Dec-2010 ::